BC 250/2 BYPASS AC

BC 250/2 BYPASS AC

The difference between this line of products and the standard type AP and APL is the resistance to pressure that, in this case, is a little lower. We therefore believe that with such pressures, the BC line is suitable for many uses into the oleo hydraulic field.

The new BC line can be equipped with an integrated by-pass valve.
It is available on the following types: BC 250, BC 250/2, BC 390, BC 390/2 e BC 390/3

The operating principle of the by-pass valve is the following: the valve is inside the lower tank, front of the oil-inlet connection; when the pressure inside the tank exceed the load spring pressure, the valve opens allowing the oil to circulate into a duct obtained inside the cooling element side instead of inside the cooling element itself.

Maximum working static pressure: 16 bar; Test pressure: 25 bar.

Oil FlowPower (DT 25°C)in/out oil sidevoltagefrequencyIP
l/min kWGASVHz
20-1606-71"230/400 or 265/46050/6054
BC 250 2 AC BYPASS

THIS IS AN EPIC
OVER 10O-YEAR-LONG HISTORY

I wrote these words in order to briefly summarize our over 100-yearlong history and share it with my current and past collaborators. While I did not personally experience the oldest parts of the story, from the beginning up to the 1950s, it was related to me orally or in writing by my father, Santo, and by uncle, Alfredo. The history from the late 1960s to the present, however, I have witnessed firsthand.

Gianluigi Sesino, President